Environmental control system

Skip to Content

Article: Environmental control system

Climate chamber of DB Systemtechnik: MEikE

MEiKE - The Minden facility for climate technical inspection of railway vehicles

Location

Minden, Pionierstraße 10

OperationStatic measurements
Use
  • Function tests for components (e.g. doors, couplings, brakes)
  • Air conditioning type tests for railway vehicles
  • Energy consumption investigations:
    -Analyses and evaluation of environmental control systems (air conditioning systems)
    -Optimisation of thermal comfort
    -Thermography analyses
    -Analyses of components used in climate control and air conditioning systems
    -Determination of the k-value of vehicles
  • Simulation of the solar radiation for the drivers´s cab
Testing conditions
  • Temperature range in test chamber from -25°C to +45°C
  • Snow and icing systems
  • Controlled humidification of the chamber air at temperatures higher than +10°C
  • Location and time-based consistency of testing condition in accordance with the relevant standards
  • Test chamber size up to 75 m x 5 m x 5 m (L x W x H)
Contact

Thomas Kwitschinski

DB Systemtechnik GmbH

Pionierstraße 10
32423 Minden

External Link DB Systemtechnik

LUDEK: Mobiler Prüfstand für Klimaanlagen von Schienenfahrzeugen

Stationäre Messungen im Klimaprüfstand Ludek

  • Funktionstests an aufgearbeiteten oder reparierten Klimaanlagen (inkl. Führerstands- und Galleyanlagen)
  • Tests bis zu 45°C bei variabler relativer Luftfeuchte
  • Energieverbrauchsmessung der Anlage („stand-alone“)
  • Untersuchungen neuer und alternativer Kältemittel
  • Stresstest unter Extrembedingungen
  • Langzeitverhalten und Verschleiß von
  • Klimaanlagen sowie Ermittlung von
  • Parametern für „Predictive Maintenance"

Dr. Peter Claus

DB Systemtechnik GmbH

Völckerstr. 5
80939 München
GERMANY